DS1101i Series Glassbreak Detectors 
.jpg) |
- Microprocessor-based sound analysis technology(SAT)
- Automatic environmental test circuitry
- Sound check
|
The DS1100i Detector Series uses microprocessorbased sound analysis technology (SAT) to listen for the specific frequencies associated with breaking glass. The DS1101i, DS1101i-BEL, DS1101i-CHI, and DS1101i-FRA can be used to detect breakage of plate, tempered, laminated and wired glass types. A built-in environmental test feature alerts the installer to false alarm hazards in harsh environments. The round detectors mount on the ceiling or walls.
Functions
Signal Processing
Audio signals are analyzed using microprocessor-based SAT and must produce specific frequency, signature, and timing relationships to cause an alarm. The sophistication of this processing technique ensures proper catch performance while eliminating false alarms.
Test Features
The magnet-operated test mode provides a location verification and operational test when using the optional DS1110i Glassbreak Tester. The test mode also includes an environmental test that alerts the installer to possible false alarm sources caused by ambient noise. The automatic sound check feature allows the end user to verify that the detector is powered and functioning by clapping his hands. An externally-visible alarm LED indicates an alarm or test condition and can be programmed to latch if desired.
|
Certifications and approvals
|
Region |
Certification |
Europe |
CE DS1101i |
USA |
UL ANSR: Intrusion Detection Units
(UL639), ANSR7: Intrusion Detection
Units Certified for Canada (ULC-S306)
DS1101i
|
Canada |
ULC |
China |
CCC DS1101i-CHI: 2009031901000553 |
Installation/configuration notes
Notice
Glassbreak detectors are intended only as a component of a perimeter protection system. They should always be used in conjunction with motion sensors.
Mounting
Mount the DS1101i series detectors on the ceiling, or on the wall opposite or adjacent to the window. Coverage depends on room acoustics and window size.
Standard Coverage
7.6 m (25 ft) for glass sizes over 30.5 cm x 30.5 cm (12 in. x 12 in.).
|
Technical specifications
Electrical
|
Current: |
23 mA at 12 VDC |
Voltage: |
6 VDC to 15 VDC |
Operating
Temperature:
|
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
|
Radio Frequency
Interference (RFI)
Immunity:
|
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
|
Dimensions
(HxDiameter):
|
2.1 cm x 8.6 cm
(0.83 in. x 3.4 in.)
|
Material: |
High-impact ABS plastic enclosure |
Alarm: |
Form C reed relay rated 3.5 W, 125 mA at
28 VDC for resistive loads.
|
Tamper: |
Normally-closed (NC) cover‑activated tamper
switch with separate terminals. Contacts rated
at 28 VDC, 125 mA maximum.
|
|